AH-60kW wind turbine
u Low rated wind speed design, high annual full service hours
u Adopt low-speed permanent magnet generator and direct drive gearless transmission design
u With active pitch control technology, the turbine group can operate continuously and smoothly within 25m/s wind speed
u Multi level safety protection such as mechanical braking, electromagnetic braking and active yaw
u The blade adopts NACA series airfoil, which has high wind energy utilization and low noise
u Equipped with the best electric control system, high efficiency and good economy
Rotor diameter(m) |
22.5 |
Blade material &Qty. |
Reinforced fiber glass*3 |
Rated power(kW) |
60 |
Max. power(kW) |
75 |
Rated wind speed(m/s) |
9 |
Rated rpm(r/min) |
60 |
Max. rpm(r/min) |
65 |
Generator type |
3 phase AC synchronous PMG |
Working wind speed(m/s) |
3-25 |
Starup wind speed(m/s) |
2.5 |
Cut-in wind speed(m/s) |
3 |
Survive wind speed(m/s) |
59.5 |
Rated voltage(VAC) |
380 |
Speed regulation method |
Active yaw+active pitch control |
Wind direction finding method |
Upwind+yaw control |
Shutdown method |
Automatic shutdown |
Gale protection |
Smart control+unattended |
Weight(kg) |
9450 |
Noise(dB) |
≤62 |
Tower height(m) |
≥30 |
Tower |
Freestanding tower |
Working temperature |
-40℃~+50℃ |
Lightning protection |
Blade lightning arrester |
Protection degree |
IP54 |
Model |
AHWI-60K |
Grid side |
|
Rated on-grid power(kW) |
60 |
Rated on-grid current(Aac) |
96 |
Rated grid voltage(Vac) |
380 |
Grid voltage range(Vac) |
340~440 |
Frequency range(Hz) |
50 ±5Hz |
THD |
<3% |
Power factor |
1 |
Grid type |
3P+N+PE |
Generator side |
|
Rated input AC power (kW) |
60 |
Max.input AC power(kW) |
78 |
Max. withstand voltage(Vac) |
780 |
MPPT voltage range(Vac) |
150-700(customized available) |
Rated input current(Aac ) |
60 |
Dump load unit |
|
Dump load method |
PMW chopper |
Power supply method |
Self supplied by generator group |
Max. withstand current(Adc) |
300 |
System |
|
Max. conversion efficiency |
98% |
Noise |
<65dB |
AC surge protection |
Yes |
AC short circuit protection |
Yes |
Protection degree |
IP54 |
Environment temperature |
-40℃~+50℃ |
Cooling method |
Forced air |
Relative humidity |
0~95% (non-condensation) |
Altitude |
2000m (Derating over 2000m) |
Emergency stop |
Yes(by pressing button) |
Display and communication |
|
Display |
7” touch screen |
Communication method |
Standard configuration: Ethernet/RS485 (MODBUS) |
Optional:WIFI/GPRS/4G |
|
Customer side monitor |
Mobile &computer APP |
Size |
|
Integrated cabinet |
2200*850*700mm |
Annual average wind speed(m/s) |
Annual average production(kW.h) |
4.5 |
108500 |
4.6 |
115000 |
4.7 |
121600 |
4.8 |
128300 |
4.9 |
135000 |
5.0 |
141600 |
5.1 |
148300 |
5.2 |
155000 |
5.3 |
161800 |
5.4 |
168400 |
5.5 |
175100 |
5.6 |
181700 |
5.7 |
188200 |
5.8 |
194700 |
5.9 |
201100 |
6.0 |
207500 |
6.1 |
213800 |
6.2 |
220000 |
6.3 |
226000 |
6.4 |
232100 |
6.5 |
238100 |
The power generation is the theoretical calculation value, and the actual power generation is related to environmental temperature, altitude, wind conditions and other factors.